products
PRODUCTS DETAILS
Home > Products >
AAAC Transmission Line Stringing Equipment 200/50 80.39kN 906kg

AAAC Transmission Line Stringing Equipment 200/50 80.39kN 906kg

MOQ: 100pieces
Price: Negotiable
Standard Packaging: Container
Delivery Period: 15-35days
Payment Method: L/C, T/T
Supply Capacity: 100000pieces/month.
Detail Information
Place of Origin
China
Brand Name
HANYU
Certification
ISO9001
Code:
200/50
Breaking Load:
80.39kn
Weight:
906kg
Diameter:
19.01mm
Areas:
247.81mm2
Type:
Aluminum Alloy Conductors Steel Reinforced
Highlight:

AAAC transmission line stringing equipment

,

200/50 stringing equipment with warranty

,

80.39kN transmission line tensioner

Product Description

Transmission Line Stringing Equipment AAAC -All Aluminum Alloy Conductors Steel Reinforced

 

Transmission line and Substation system

 

Conductor Type:

  • AAC-All Aluminum Conductors
  •  
  • ACS-aluminum-clad steel conductors
  • AAAC -All Aluminum Alloy Conductors
  • ACSR- Aluminum Conductors Steel Reinforced
  • AACSR-Aluminum Alloy Conductors Steel Reinforced
  • ACAR-All Aluminum Conductor Alloy Reinforced
  • GSW-Zinc-Coated (Galvanized) Steel Overhead Ground Wire Strand
  • ACSR/AW -Aluminum Conductors Aluminum Clad Steel Reinforced
Code Structure Areas Diameter Breaking load

DC

resistance at 20℃

Weight Curent capacity
Al Steel TACIR ZTACIR
Nos/mm mm2 mm kN 2/km Kg/km A
160/40 18/337 7/2.65 199.16 17.04 65.06 0.1759 730 71 957
200/45 17/387 7/285 244.62 18.87 76.87 0.1412 883 890 1105
200/50 17/387 7/295 24781 19.01 80.39 0.1409 906 892 1110
250/45 18/420 7/285 294.04 20.64 8264 0.1141 1019 1017 1268
250/40 18/4.13 7/275 290.96 20.51 8112 0.1143 996 1014 1264
240/55 18/4.13 7/3.20 29743 20.82 9312 0.1169 1083 1007 1138
240/50 18/471 7/3.00 290.62 20.55 88.13 0.1157 1032 1000 1131
315/55 18/471 7/3.20 396.92 2315 104.06 0.0907 1266 1182 1479
315/50 18/471 7/3.00 36310 2291 97.20 0.0910 1232 1176 1471
330/60 18/481 7/330 386.95 2368 10970 0.0869 1329 1216 1522
350/55 20/471 7/3.20 404.77 2419 10933 0.0819 1379 1262 1580
Technical details
  • Invar Conductor
  • Invar Conductor made is a kind of special overhead conductor stranded with high-strength aluminum-clad invar core and super thermal resistant aluminum alloy wire. It takes advantage of the low linear expansion coefficient of invar material to make "low sag" and uses a thermal resistant aluminum alloy to have " large-capacity", making full use of original transmission line and tower resources and saving space. It has the feature of doubling capacity with the same diameter and the same sag, which can ensure power transmission at peak season.
Characteristics
  • 2 times current carrying capacity without increasing sag.
  • More economical for fittings.
  • Easier installation than ACCC Conductor.
  • More reliable operation experience.
  • In compliance with or exceeding the industry’s most stringent requirements, including:
  • IEC 62004
  • IEC 61089
  • IEC 62219
  • Q/320623-AP25
Applications
  • Reconstruction of old transmission lines.
  • Capacity increasing transmission line.

 

AAAC Transmission Line Stringing Equipment 200/50 80.39kN 906kg 0

 

products
PRODUCTS DETAILS
AAAC Transmission Line Stringing Equipment 200/50 80.39kN 906kg
MOQ: 100pieces
Price: Negotiable
Standard Packaging: Container
Delivery Period: 15-35days
Payment Method: L/C, T/T
Supply Capacity: 100000pieces/month.
Detail Information
Place of Origin
China
Brand Name
HANYU
Certification
ISO9001
Code:
200/50
Breaking Load:
80.39kn
Weight:
906kg
Diameter:
19.01mm
Areas:
247.81mm2
Type:
Aluminum Alloy Conductors Steel Reinforced
Minimum Order Quantity:
100pieces
Price:
Negotiable
Packaging Details:
Container
Delivery Time:
15-35days
Payment Terms:
L/C, T/T
Supply Ability:
100000pieces/month.
Highlight

AAAC transmission line stringing equipment

,

200/50 stringing equipment with warranty

,

80.39kN transmission line tensioner

Product Description

Transmission Line Stringing Equipment AAAC -All Aluminum Alloy Conductors Steel Reinforced

 

Transmission line and Substation system

 

Conductor Type:

  • AAC-All Aluminum Conductors
  •  
  • ACS-aluminum-clad steel conductors
  • AAAC -All Aluminum Alloy Conductors
  • ACSR- Aluminum Conductors Steel Reinforced
  • AACSR-Aluminum Alloy Conductors Steel Reinforced
  • ACAR-All Aluminum Conductor Alloy Reinforced
  • GSW-Zinc-Coated (Galvanized) Steel Overhead Ground Wire Strand
  • ACSR/AW -Aluminum Conductors Aluminum Clad Steel Reinforced
Code Structure Areas Diameter Breaking load

DC

resistance at 20℃

Weight Curent capacity
Al Steel TACIR ZTACIR
Nos/mm mm2 mm kN 2/km Kg/km A
160/40 18/337 7/2.65 199.16 17.04 65.06 0.1759 730 71 957
200/45 17/387 7/285 244.62 18.87 76.87 0.1412 883 890 1105
200/50 17/387 7/295 24781 19.01 80.39 0.1409 906 892 1110
250/45 18/420 7/285 294.04 20.64 8264 0.1141 1019 1017 1268
250/40 18/4.13 7/275 290.96 20.51 8112 0.1143 996 1014 1264
240/55 18/4.13 7/3.20 29743 20.82 9312 0.1169 1083 1007 1138
240/50 18/471 7/3.00 290.62 20.55 88.13 0.1157 1032 1000 1131
315/55 18/471 7/3.20 396.92 2315 104.06 0.0907 1266 1182 1479
315/50 18/471 7/3.00 36310 2291 97.20 0.0910 1232 1176 1471
330/60 18/481 7/330 386.95 2368 10970 0.0869 1329 1216 1522
350/55 20/471 7/3.20 404.77 2419 10933 0.0819 1379 1262 1580
Technical details
  • Invar Conductor
  • Invar Conductor made is a kind of special overhead conductor stranded with high-strength aluminum-clad invar core and super thermal resistant aluminum alloy wire. It takes advantage of the low linear expansion coefficient of invar material to make "low sag" and uses a thermal resistant aluminum alloy to have " large-capacity", making full use of original transmission line and tower resources and saving space. It has the feature of doubling capacity with the same diameter and the same sag, which can ensure power transmission at peak season.
Characteristics
  • 2 times current carrying capacity without increasing sag.
  • More economical for fittings.
  • Easier installation than ACCC Conductor.
  • More reliable operation experience.
  • In compliance with or exceeding the industry’s most stringent requirements, including:
  • IEC 62004
  • IEC 61089
  • IEC 62219
  • Q/320623-AP25
Applications
  • Reconstruction of old transmission lines.
  • Capacity increasing transmission line.

 

AAAC Transmission Line Stringing Equipment 200/50 80.39kN 906kg 0