products
PRODUCTS DETAILS
Home > Products >
FR-2 Light Wind Vibration Stockbridge Damper For Transmission Line Wire

FR-2 Light Wind Vibration Stockbridge Damper For Transmission Line Wire

MOQ: 30pieces
Price: Negotiable
Standard Packaging: Case
Delivery Period: 15-35days
Payment Method: L/C, T/T
Supply Capacity: 6000pieces/month.
Detail Information
Place of Origin
China
Brand Name
HANYU
Certification
ISO9001
Model Number
FR-2
Type:
Anti-vibration Hammer For Conductor
Dimension A:
50mm
Dimension H:
80mm
Dimensions L1:
239mm
Dimensions L:
429mm
Dimensions L2:
190mm
Applicable Conductor):
11-22
Usage:
Protecting The Anti-vibration And Anti-vibration Of The Transmission Line Wire
Highlight:

Light Wind Vibration Stockbridge Damper

,

Transmission Line Stockbridge Damper

,

stockbridge damper in transmission line

Product Description

Powerline Tools Light Wind Vibration Stock Bridge Damper Interval Dampers

 

  • FR series spacer dampers can effectively prevent damage to conductors and static wires caused by wind vibration caused by wind or airflow.
  • The Stockbridge damper is composed of a certain mass of weight, high elasticity, high strength zinc steel strands and clamps.
  • The installation position of the Stockbridge damper should be determined according to the construction requirements.
  • After the Stockbridge damper is installed, it can produce a movement opposite to the vibration of the wire, thereby eliminating or reducing the unsteady vibration of the wire.
 
ltem No. Applicable conductor Dimensions Weight
L1 L2 h a L
mm mm Kg
FR-1 7-12 239 190 80 50 429 2.6
FR-2 11-22 239 190 80 50 429 2.6
FR-3 18-28 280 225 90 60 505 4.5
FR-4 23-36 300 250 97 60 550 4.97
 

Descrption

  • Stockbridge dampers are designed to reduce wind-induced vibration of wires. The cable accessory is an indispensable part of overhead transmission lines. As a professional manufacturer of cables and cable accessories, we can provide you with specific and complete advice on cable accessories to ensure the integrity of the entire electrical system.
  • We are dedicated to the production and research of global power supply. Because only high-quality cables and cable accessories have production value.
 

Stockbridge Damper Instructions

  • Common anti-vibration methods include installing Stockbridge dampers, damper wires, or a combination of Stockbridge dampers and damper wires.
  • High-frequency vibrations are mainly damped by damping wires, and low-frequency vibrations are mainly damped by anti-vibration dampers.
  • Due to the small span and the low suspension point of the wire, the ordinary span wire generally uses an anti-vibration hammer to prevent vibration.
  • When vibrating, the wire drives the anti-vibration hammer to vibrate together, and the vibration energy of the wire is absorbed by the anti-vibration hammer, thereby protecting the anti-vibration and anti-vibration of the transmission line wire.
  • Due to the long vibration time under strong wind conditions, it is required to limit the amplitude to a low level, and the amplitude should not exceed 50% of the normal gear.
  • Generally, a combination of damping wire and shock absorber is used. In addition, in some areas where wind vibration conditions are particularly severe, Stockbridge dampers cannot meet the requirements, and damping wires and Stockbridge dampers must be used to suppress wind vibration.

 

FR-2 Light Wind Vibration Stockbridge Damper For Transmission Line Wire 0

products
PRODUCTS DETAILS
FR-2 Light Wind Vibration Stockbridge Damper For Transmission Line Wire
MOQ: 30pieces
Price: Negotiable
Standard Packaging: Case
Delivery Period: 15-35days
Payment Method: L/C, T/T
Supply Capacity: 6000pieces/month.
Detail Information
Place of Origin
China
Brand Name
HANYU
Certification
ISO9001
Model Number
FR-2
Type:
Anti-vibration Hammer For Conductor
Dimension A:
50mm
Dimension H:
80mm
Dimensions L1:
239mm
Dimensions L:
429mm
Dimensions L2:
190mm
Applicable Conductor):
11-22
Usage:
Protecting The Anti-vibration And Anti-vibration Of The Transmission Line Wire
Minimum Order Quantity:
30pieces
Price:
Negotiable
Packaging Details:
Case
Delivery Time:
15-35days
Payment Terms:
L/C, T/T
Supply Ability:
6000pieces/month.
Highlight

Light Wind Vibration Stockbridge Damper

,

Transmission Line Stockbridge Damper

,

stockbridge damper in transmission line

Product Description

Powerline Tools Light Wind Vibration Stock Bridge Damper Interval Dampers

 

  • FR series spacer dampers can effectively prevent damage to conductors and static wires caused by wind vibration caused by wind or airflow.
  • The Stockbridge damper is composed of a certain mass of weight, high elasticity, high strength zinc steel strands and clamps.
  • The installation position of the Stockbridge damper should be determined according to the construction requirements.
  • After the Stockbridge damper is installed, it can produce a movement opposite to the vibration of the wire, thereby eliminating or reducing the unsteady vibration of the wire.
 
ltem No. Applicable conductor Dimensions Weight
L1 L2 h a L
mm mm Kg
FR-1 7-12 239 190 80 50 429 2.6
FR-2 11-22 239 190 80 50 429 2.6
FR-3 18-28 280 225 90 60 505 4.5
FR-4 23-36 300 250 97 60 550 4.97
 

Descrption

  • Stockbridge dampers are designed to reduce wind-induced vibration of wires. The cable accessory is an indispensable part of overhead transmission lines. As a professional manufacturer of cables and cable accessories, we can provide you with specific and complete advice on cable accessories to ensure the integrity of the entire electrical system.
  • We are dedicated to the production and research of global power supply. Because only high-quality cables and cable accessories have production value.
 

Stockbridge Damper Instructions

  • Common anti-vibration methods include installing Stockbridge dampers, damper wires, or a combination of Stockbridge dampers and damper wires.
  • High-frequency vibrations are mainly damped by damping wires, and low-frequency vibrations are mainly damped by anti-vibration dampers.
  • Due to the small span and the low suspension point of the wire, the ordinary span wire generally uses an anti-vibration hammer to prevent vibration.
  • When vibrating, the wire drives the anti-vibration hammer to vibrate together, and the vibration energy of the wire is absorbed by the anti-vibration hammer, thereby protecting the anti-vibration and anti-vibration of the transmission line wire.
  • Due to the long vibration time under strong wind conditions, it is required to limit the amplitude to a low level, and the amplitude should not exceed 50% of the normal gear.
  • Generally, a combination of damping wire and shock absorber is used. In addition, in some areas where wind vibration conditions are particularly severe, Stockbridge dampers cannot meet the requirements, and damping wires and Stockbridge dampers must be used to suppress wind vibration.

 

FR-2 Light Wind Vibration Stockbridge Damper For Transmission Line Wire 0